ICU Ventilation · Tracheostomy Care · Inline Suction

Closed Suction Catheter

Closed suction catheter system for ventilated patients. Designed to help maintain PEEP and oxygenation while reducing ventilator circuit disconnections during airway suction.

ETT / Trach Inline Options Closed suction catheter inline suction system
Closed Circuit Suction Inline suction helps maintain ventilation support without repeatedly disconnecting the circuit.
Configurable System ETT Y-adapter, tracheostomy T-adapter, lavage port, double swivel and 24 / 48 / 72 h options.
ETT / Trach 5–16 Fr 24 / 48 / 72 h Lavage Port Optional Double Swivel EO Sterile
Size MatrixAdult, pediatric or neonatal French sizes.
Adapter TypeETT inline Y-adapter or trach T-adapter.
Change Interval24 h, 48 h or 72 h use period.
Quote-Ready Details

What Buyers Usually Confirm Before Sending an RFQ

Share the key closed suction details below and we can help match the correct system, packaging option and sample arrangement faster.

Patient CategoryAdult, pediatric or neonatal application.
Feature OptionLavage port, double swivel, depth marks or radiopaque line.
Connection TypeETT inline Y-adapter or tracheostomy T-adapter.
Order PlanMonthly quantity, destination market and artwork request.
Need closed suction systems for ICU, tracheostomy care or distributor supply? Tell us adapter type, French size, change interval, optional features, monthly quantity and destination market. We will help build a quote-ready configuration.
Request Quote

Why Choose Closed Suction Catheters

Designed for procurement teams that need stable inline suction performance, clear configuration options and reliable respiratory disposable supply.

01

Maintain PEEP

Closed suction allows airway suction without breaking the ventilator circuit, helping maintain PEEP and oxygenation.

02

Reduce Disconnections

Inline connection helps reduce repeated circuit opening and supports a cleaner workflow in ICU ventilation.

03

Flexible Adapters

Choose ETT inline Y-adapter, tracheostomy T-adapter, lavage port, double swivel and cleaning chamber options.

04

OEM Ready Supply

Private label pouch, carton label, barcode, IFU support and market-specific export packaging can be discussed.

Select Closed Suction Configuration

Click one option to sync it with both RFQ forms. This helps your quotation request include the exact adapter type and feature set.

Ventilator Circuit Option

ETT Inline Y-Adapter

For endotracheal tube connection, helping maintain a closed circuit during routine airway suction.

  • Adult and pediatric French sizes
  • 24 / 48 / 72 h change interval
  • Optional irrigation / lavage port
Tracheostomy Care

Tracheostomy T-Adapter

Direct T-piece adapter for tracheostomy tubes with easy inline connection and suction control.

  • Adult / pediatric / neonatal options
  • One-way lavage valve optional
  • Swivel connector option available
Advanced Configuration

Pro Lavage + Double Swivel

Integrated irrigation port, double swivel, splash shield cleaning chamber and transparent protective sleeve.

  • Depth marks and radiopaque line optional
  • 15F / 22M / 22F ISO conical connectors
  • OEM pouch and carton support

At-a-Glance Buying Information

Use these common buying details to prepare a faster quotation request.

Product TypeClosed Suction Catheter

Inline suction catheter system for ventilated patients.

Patient Size5–16 Fr

Neonatal, pediatric and adult French size options.

Interval24 / 48 / 72 h

Change interval can be selected according to hospital policy.

Packaging1 Set / Pouch

OEM label, carton and market-specific packing available.

Technical Specifications

Final specification can be adjusted according to patient group, French size, adapter type, change interval, lavage port request and packaging requirement.

Product NameClosed Suction Catheter
TypeClosed inline suction catheter system for ventilated patients
SizesNeonatal / pediatric 5–10 Fr; adult 10–16 Fr; color-coded hubs available
Change Interval24 h, 48 h, 72 h according to hospital policy and product configuration
Adapter OptionsETT inline Y-adapter, tracheostomy T-adapter, 15F / 22M / 22F ISO conical connectors
Feature OptionsCleaning chamber with splash shield, irrigation / lavage port, double swivel, thumb suction control
MarkingsCentimeter depth markings and radiopaque line optional
MaterialsMedical PVC / TPE catheter, TPU / PE protective sleeve, latex-free and DEHP-free options available
SterilizationEO sterile, single-use packaging available
ComplianceISO 8836, ISO 5356-1, ISO 10993, ISO 13485 QMS
Packaging1 set / pouch, 50–100 sets / carton, custom packaging available

Before clinical use, verify connector compatibility, catheter size, sleeve integrity and suction control function according to local IFU and hospital protocol.

Quick Setup Guide

Clear connection steps help clinical teams reduce preparation time and confirm the closed suction system before patient use.

01

Connect Adapter

Attach the inline adapter to the ventilator circuit and ETT or tracheostomy tube.

02

Set Vacuum

Connect suction tubing, set vacuum level according to protocol and confirm valve operation.

03

Perform Suction

Advance catheter, apply suction, rotate and withdraw; flush in the cleaning chamber when used.

04

Maintain / Replace

Keep sleeve intact and replace according to 24 / 48 / 72 h policy or contamination status.

Procurement & OEM Support

Built for B2B respiratory disposable buyers who need clear closed suction configuration, sample-first confirmation and practical packaging support.

Buyer Support

Build a Closed Suction Catheter Configuration for Your Market

Confirm patient category, French size, adapter type, change interval, lavage port, double swivel, label language and carton details. Our team can help convert your requirement into a clear quotation and sample configuration.

Send Detailed RFQ
Closed suction catheter procurement support
01

Size Confirmation

Confirm adult, pediatric or neonatal French size range before sample arrangement and bulk order.

02

OEM Label & Carton

Private label pouch, carton artwork, barcode and market-specific information can be discussed.

03

Sample Arrangement

Sample-first confirmation helps verify adapter fit, catheter smoothness, sleeve strength and packaging details.

Frequently Asked Questions

Common questions from hospitals, ICU product distributors and respiratory disposable procurement teams.

Does closed suction help maintain PEEP?

Yes. Closed suction allows airway suction without disconnecting the ventilator circuit, helping maintain PEEP and oxygenation.

Which adapter should I choose?

ETT inline Y-adapter is used for endotracheal tubes. Tracheostomy T-adapter is used for tracheostomy care. Final choice depends on clinical setup.

What change interval is available?

24 h, 48 h and 72 h systems can be discussed according to hospital policy and target market requirement.

Can I request lavage port or double swivel?

Yes. Lavage port, one-way valve, double swivel, splash shield cleaning chamber and depth markings can be configured.

Are neonatal and pediatric sizes available?

Yes. Neonatal and pediatric French size options are available, usually 5–10 Fr depending on configuration.

What information should I send for a fast quote?

Please provide adapter type, patient category, French size, change interval, optional features, monthly quantity, destination market and packaging request.

Detailed RFQ Form

For accurate quotation, please include adapter type, French size range, change interval, optional features, packaging request and estimated order volume.

What to Include
  • ETT inline Y-adapter or tracheostomy T-adapter
  • Adult, pediatric or neonatal French size range
  • 24 h, 48 h, 72 h or custom change interval request
  • Lavage port, double swivel, depth marks or radiopaque line request
  • Monthly quantity, destination market and packaging requirement
Support

OEM / ODM, pouch artwork, carton label support, sample arrangement and export packaging can be discussed according to your closed suction catheter specification and target market requirements.

Selected: General Closed Suction Catheter Inquiry

    Name*

    Email*

    WhatsApp / Phone*

    Company / Organization

    Country / Destination Market

    Patient Category

    Adapter Type

    French Size Range

    Change Interval

    Estimated Monthly Quantity

    Required Features

    Detailed Requirement

    Ready to Source Closed Suction Catheters?

    Send your configuration and monthly quantity. Our team will help confirm product option, packaging, quotation and sample arrangement.