Jackson-Pratt (JP) Drain Bulb
Jackson-Pratt (JP) drain bulb for closed-suction post-operative drainage. Designed with soft compressible bulb, clear graduations, self-sealing port, secure connector options and optional anti-reflux valve for clinical drainage management.
Compressible bulb helps maintain negative pressure after the self-sealing port is closed.
Transparent bulb body with printed scale supports easier drainage volume observation.
100 mL, 200 mL, 400 mL or customized drainage bulb capacity.
Universal tapered connector, luer option or customized connector design.
EO sterile pouch, private label and export carton options available.
Tell us bulb capacity, connector type, valve option, sterile packaging and monthly quantity.
Why Choose Jackson-Pratt Drain Bulbs
Designed for closed-suction drainage where stable negative pressure, clear volume reading and secure connection are important.
Closed Suction
Soft bulb can be compressed to create negative pressure and support continuous drainage collection.
Clear Graduations
Transparent bulb body and printed mL scale help clinical users monitor drainage volume.
Secure Connection
Tapered or luer connector options help match different drain tubing requirements.
OEM Ready Supply
Capacity, connector, valve, pouch label and carton artwork can be customized for your market.
Product Overview
Review bulb capacity, connector, cap, self-sealing port, anti-reflux valve option and sterile packaging before confirming your specification.
Commonly used with compatible JP drains for post-operative drainage collection and monitoring.
100 / 200 / 400 mL
Choose compact, standard or high-capacity bulb according to expected drainage output and market requirement.
Tapered / Luer / Anti-Reflux
Universal tapered connector, luer option, self-sealing port and anti-reflux valve can be discussed.
Select JP Drain Bulb Configuration
Click one option to sync the selected configuration with both RFQ forms. This helps your inquiry include a clear product request.
100 mL JP Drain Bulb
Compact size for lower exudate volumes with easy one-hand compression and secure cap closure.
- Standard self-sealing port
- Tapered outlet connector
- EO sterile pouch available
200 mL JP Drain Bulb
Balanced capacity for routine post-operative drainage with optional anti-reflux valve design.
- Clear printed graduations
- Anti-reflux valve option
- Tapered or luer connector
400 mL JP Drain Bulb
Higher-capacity bulb for higher output cases with optional stay-put hanger loop and connector options.
- Large volume collection
- Clear easy-read scale
- Valve and connector options
At-a-Glance Buying Information
Use these common buying details to prepare a faster quotation request.
Closed-suction drain collection bulb for compatible drainage tubes.
100 mL, 200 mL, 400 mL and custom capacity options.
Universal tapered connector, luer option or custom connector.
EO sterile pouch, OEM label and export carton available.
Technical Specifications
Final specification can be adjusted according to bulb capacity, connector, valve, scale printing, material and packaging requirement.
| Product Name | Jackson-Pratt (JP) Drain Bulb |
|---|---|
| Type | Closed-suction drain collection bulb for compatible JP drain tubing |
| Capacities | 100 mL, 200 mL, 400 mL; custom capacity available on request |
| Ports | Self-sealing medication / emptying port; optional anti-reflux valve |
| Scale | Clear mL graduations; low-glare surface option available |
| Connections | Universal tapered connector and / or luer connector options for drain tubing sets |
| Materials | Medical-grade silicone bulb; PP / PE caps; latex-free and DEHP-free options available |
| Sterilization | EO sterile, single-use packaging |
| Compliance | ISO 13485 quality management system; ISO 10993 biocompatibility support |
| Packaging | 1 pc / pouch, 50–100 pcs / carton; private label and custom carton available |
Use with compatible JP drains and follow hospital protocol. Maintain negative pressure by fully compressing the bulb before closing the port.
Quick Setup Guide
Clear setup steps help clinical teams prepare and manage JP drain bulbs correctly.
Prime & Compress
Open the port, fully compress the bulb to create negative pressure, then close the cap securely.
Connect
Attach to drain tubing through tapered or luer connector and ensure a tight, leak-free fit.
Secure
Use hanger or clip to position below the wound level and avoid kinks or tubing tension.
Empty & Record
Open the port, drain to container, measure volume by scale and re-compress the bulb.
Procurement & OEM Support
Built for hospitals, distributors and medical disposable buyers who need stable JP drain bulb supply and clear configuration support.
Build a JP Drain Bulb for Your Market
Confirm capacity, connector type, anti-reflux valve, self-sealing port, scale printing, material option, sterile pouch, carton label and destination market. Our team can help convert your requirement into a clear quotation and sample configuration.
Send Detailed RFQ
Configuration Confirmation
Confirm capacity, connector, valve, cap design, scale printing and sterile packaging before sample arrangement.
OEM Label & Carton
Private label pouch, carton artwork, barcode and market-specific information can be discussed.
Sample Arrangement
Sample-first confirmation helps verify bulb softness, suction recovery, connector fit, cap seal and packaging details.
Frequently Asked Questions
Common questions from hospitals, distributors and post-operative drainage disposable procurement teams.
How do I maintain suction?
Fully compress the bulb, then close the self-sealing port. The bulb re-expands slowly to create steady negative pressure.
Do I need an anti-reflux valve?
The optional valve helps reduce backflow during movement, handling or emptying. It can be selected according to clinical workflow.
Which capacity should I choose?
100 mL is suitable for lower output, 200 mL for typical post-operative drainage and 400 mL for higher output cases.
Is it sterile and latex-free?
Yes. EO sterile, single-use and latex-free options are available. DEHP-free materials can also be discussed.
Can I request custom connector or scale printing?
Yes. Connector type, scale style, valve option, pouch label and carton information can be customized according to your market.
What information should I send for a fast quote?
Please provide capacity, connector type, valve request, sterile packaging, monthly quantity, destination market and sample request.
Detailed RFQ Form
For accurate quotation, please include bulb capacity, connector type, anti-reflux valve, scale printing, sterility, packaging request and estimated order volume.
- Bulb capacity: 100 mL, 200 mL, 400 mL or custom
- Connector type: tapered connector, luer connector or custom connector
- Self-sealing port, anti-reflux valve and cap design request
- Scale printing, EO sterile pouch and OEM label requirement
- Monthly quantity, destination market and sample request
OEM / ODM, private pouch artwork, carton label support, sample arrangement and export packaging can be discussed according to your JP drain bulb specification and target market requirements.
Ready to Source Jackson-Pratt Drain Bulbs?
Send your capacity, connector type and monthly quantity. Our team will help confirm product option, packaging, quotation and sample arrangement.





















